By 20 Aprile 2020 Read More →

Vmware Converter – FAILED: Unable to create a VSS snapshot of the source volume(s). Error code: 259 (0x00000103)

Se utilizzando Vmware Converter si riceve l’errore:

FAILED: Unable to create a VSS snapshot of the source volume(s). Error code: 259 (0x00000103)

utilizzare questo set di istruzioni :

cd /d %windir%system32
Net stop vss
Net stop swprv
regsvr32 /s ole32.dll
regsvr32 /s oleaut32.dll
regsvr32 /S vss_ps.dll
Vssvc /Register
regsvr32 /s /i swprv.dll
regsvr32 /s /i eventcls.dll
regsvr32 /s es.dll
regsvr32 /s stdprov.dll
regsvr32 /s vssui.dll
regsvr32 /s msxml.dll
regsvr32 /s sxml3.dll
regsvr32 /s msxml4.dll
Net start vss
Net start swprv

Solitamente non è necessario il riavvio della macchina.
Verificare anche le copie Shadow del Volume. Tenere presente che Vmware Converter non lavora con partizioni FAT o FAT32.

Vmware Converter Unable to create a VSS snapshot of the source volume(s). Error code: 259 (0x00000103), Vmware Converter Error code: 259 (0x00000103)